    PCI Sample Concentrators

    PCI Nitrogen Concentrator for fast and controlled sample evaporation

    Precision sample concentrator designed for nitrogen purging and multiple sample pre-concentration in organic media, with controlled temperature and stable gas flow for dependable evaporation performance.

    PCINitrogen PurgingSample EvaporationTabletop System
    Add PCI Nitrogen Concentrator image here
    TemperatureAmbient to 90°C
    Timer Range15 sec to 10 hrs
    Gas SupplyLaboratory Grade Nitrogen
    ModelsEV-PLUS-50 / EV-PLUS-100

    Product Overview

    Single-product category presentation for PCI nitrogen concentrator systems.

    The PCI Nitrogen Concentrator is a precision sample concentrator by nitrogen purging, developed for multiple sample pre-concentration in organic media. It is a tabletop system that can be set to constant flow and constant temperature for efficient and repeatable evaporation. [file:15]

    The brochure highlights two working configurations: EV-PLUS-100 for higher sample capacity operation and EV-PLUS-50 for low-volume concentration work. Both models use microprocessor-based control, digital display, timer-based operation, and built-in exhaust arrangements. [file:15]

    Key Features

    • Nitrogen purging based sample concentration. [file:15]
    • Constant temperature operation for controlled evaporation. [file:15]
    • Constant flow setup for repeatable performance. [file:15]
    • Fully microprocessor based controller. [file:15]
    • Digital LCD display. [file:15]
    • Built-in exhaust in EV-PLUS models. [file:15]

    Applications

    • Multiple sample pre-concentration in organic media. [file:15]
    • Routine laboratory sample evaporation workflows. [file:15]
    • Controlled nitrogen blowdown concentration. [file:15]
    • Low-volume tube concentration with the EV-PLUS-50 rack formats. [file:15]
    • High-throughput concentration up to 100 samples with EV-PLUS-100. [file:15]

    Installation Requirements

    • Table top or fume hood space of minimum 70 x 50 x 65 cm with 35 kg table load capacity. [file:15]
    • Flat, levelled, stable work area. [file:15]
    • 230 AC single-phase well-grounded power supply. [file:15]
    • Laboratory grade nitrogen supply. [file:15]
    • Inlet pressure between 60 and 100 PSI with ON/OFF control valve. [file:15]

    Safety & Operation

    • Temperature range up to 90°C with thermal cutoff for safety. [file:15]
    • Green LED indication when process is ON. [file:15]
    • Error indication through buzzer or LED with buzzer, depending on model. [file:15]
    • Exhaust duct must go outside the lab for general technical installation guidance. [file:15]
    • Do not operate the instrument without the exhaust duct. [file:15]

    Model Options

    PCI nitrogen concentrator configurations from the brochure.

    PCIHigh Capacity

    EV-PLUS-100

    High-capacity nitrogen concentrator with 100 sample capacity, 10 gas lines, microprocessor control, digital LCD display, and built-in exhaust. [file:15]

    Capacity100 Samples
    Gas Lines10 Nos.
    Gas Use30 LPM
    Water Tank6.5 Ltrs.
    PCILow Volume

    EV-PLUS-50

    Low-volume sample concentrator with 50 sample capacity, 5 gas stations, 5 gas lines, microprocessor-based control, digital LCD display, and built-in exhaust. [file:15]

    Capacity50 Samples
    Gas Lines5 Nos.
    Water Tank6.5 Ltr.
    Power230 V AC / 6 Amp

    Technical Specifications

    Detailed specifications from the PCI brochure.

    SpecificationEV-PLUS-100EV-PLUS-50
    Product TypeNitrogen Concentrator / Sample Evaporator [file:15]Nitrogen Concentrator / Sample Evaporator [file:15]
    Time Range15 sec to 10 hours [file:15]15 sec to 10 hours [file:15]
    Time SettingUP / DOWN arrow keys, 15 sec increments [file:15]UP / DOWN arrow keys, 15 sec increments [file:15]
    Temperature RangeAmbient to 90°C with thermal cut off [file:15]Ambient to 90°C with thermal cutout [file:15]
    Temperature SettingUP / DOWN arrow keys, 1°C increment [file:15]
    DisplayLCD digital [file:15]LCD digital [file:15]
    ControllerFully microprocessor based [file:15]Fully microprocessor based [file:15]
    Start / Stop IndicationGreen LED when process is ON [file:15]Green LED when process is ON [file:15]
    Sample Capacity100 Nos. [file:15]50 Nos. [file:15]
    Gas Consumption30 LPM [file:15]Not specified [file:15]
    Gas StationsNot specified separately [file:15]5 Nos. with LED indication [file:15]
    Gas Lines10 Nos. (1-10 samples per line, nozzle caps provided) [file:15]5 Nos. (1-10 samples per line, nozzle caps provided) [file:15]
    Pressure Regulator Range0 - 100 PSI [file:15]0 - 100 PSI approximate [file:15]
    Pressure Gauge Range0 - 100 PSI [file:15]0 - 100 PSI [file:15]
    Water Tank Capacity6.5 Ltrs. [file:15]6.5 Ltr. [file:15]
    Dimensions540 x 380 x 590 mm (H x W x L) [file:15]600 x 520 x 400 mm [file:15]
    Weight35 kgs. empty tank [file:15]25 kgs. empty tank [file:15]
    ExhaustBuilt-in exhaust, no fume hood required [file:15]Built-in exhaust, no fume hood required [file:15]
    Error IndicationBuzzer sound [file:15]LED indication with buzzer [file:15]
    Power Supply230 V AC / 6 Amp [file:15]230 V AC / 6 Amp [file:15]

    EV-PLUS-50 Rack Specifications

    Tube size compatibility and working volumes from the brochure.

    Rack TypeWorking Volume
    12 mm x 75 mm4 ml [file:15]
    12 mm x 100 mm5 ml [file:15]
    16 mm x 100 mm (Standard)10 ml [file:15]
    15 mm x 125 mm11 ml [file:15]
    15 mm x 150 mm12 ml [file:15]
    17 mm x 125 mm15 ml [file:15]
    18 mm x 150 mm20 ml [file:15]
    20 mm x 150 mm30 ml [file:15]

    The brochure also notes a general installation requirement of laboratory grade nitrogen, inlet pressure between 60 and 100 PSI, and stable, level placement. [file:15]